HY series usual inverter, VFD inverter
Product Model
Specification
N.T
(kg)
DimensionÂ
(mm)
HY0D7528B
220V/0.75KW
1.6Â
168Ã124Ã160
HY01D523B
220V/1.5KW
1.6
168Ã124Ã160
HY02D223B
220V/2.2KW
1.6
168Ã124Ã160
HY03D023B
220V/3.0KW
2.0
168Ã124Ã160
Technical parameter specification
Series
HYÂ inverters
Control Mode
SPWM
Input Power
380V class:380±15%ï¼230V class:220±15%
5-Digits Display &Â
Status Indicator Lamp
Displaying frequency,  current,  revolution, Â
voltage, Â counter, Â temperature, Â
FOR or REV rotation,  and fault,  etc.
Communication Control
RS-485
Working Temperature
-10~40â
Humidity
0-95% Relative Humidity(without dew)
Vibration
Below 0.5G
FrequencyÂ
Control
Range
0.1~2500.0Hz
Accuracy
Digital:Â 0.1%(-10~40â);Â
Analog: 0.1% (25±10â)
Setting Resolution
Digital: 0.1Hz; Analog: 1â°Â of max.Â
Operating frequency
Output Resolution
0.1Hz
Operator Setting Method
Press directly â â§Â â¨Â to set.
Analog Setting Method
External Voltage 0-5V, 0-10V,
4-20mA, 0-20mA.
Other Functions
Frequency lower limit,  starting frequency, Â
stopping frequency,  three skip frequencies can be respectively set.Â
GeneralÂ
Control
Ramp Control
Selectable 4-speed steps ramp-up and -down time (0.1-6500s).Â
V/FÂ Curve
Set V/F curve at will.
Torque Control
Torque increase settable by max. 10.0%.Â
The starting torque can reach 150% at 1.0Hz.Â
Multi-Inputs
6 multi-function input terminals for 8âspeed steps control, Â
program operation,  switching of 4-speed Ramp, Â
UP/DOWN function,  counter,  external emergency stop and other functions.Â
Multi-OutputsÂ
5 multi-output for displaying of running, Â
zero speed,  counter,  external abnormity, Â
program operation and other information and warnings.
Other Functions
Auto Voltage Regulation(AVR),  Decelerating Stop or Coasting Stop, Â
DC Braking,  Auto Reset and Restart,  Frequency Track, Â
PLC Program Control,  Traverse Control,  Drawing Control,
Auto Energy Saving,  Carrier Adjustable (Up to 20KHz),  etc.Â
ProtectionÂ
Functions
Overload Protection
Electronic relay protection motor drive
Drive(for constant torque  150%/1 min. for the kinds of fan 120%/1min.)
Fuse Protection
When the fuse breaks ,  the motor will stop.
Over-voltage
220V class:DC Voltage ï¼400V
380V class:DC Voltage ï¼800V
Under-voltage
220V class:DC Voltage ï¼200V
380V class:DC Voltage ï¼400V
Restart AfterÂ
Instant Stop
Restart with Frequency Track after Instant Stop
Stall Protection
Stall protection in ramp operation
Output Short Circuit
Electrical circuit protection
Other Functions
Fin over-heat protection,  restriction of reverse running, Â
direct start after power on,  fault reset,  parameter lock PID, Â
one-drive-more, Â etc.
Terminal compositor
Symbol
Function Description
R.S.T
Input terminal of AC line power.
(220V class,  for both single/three phase, Â
single phase connected to any two phases)
U.V.W
Output terminal of the inverter
PÂ Â Pr
Connector for braking resistor.
E
Ground terminal: the third method of grounding for 220V and special groundingÂ
for 380 V of Electrical Engineering Regulations.
Function Description of Control Circuit Terminals
UPF
DRV
DCM
SPL
SPM
SPH
RST
REV
FOR
ACM
VO
10V
FA
FC
FB
KA
KB
AI
VI
RS+
RS-
Symbol
Function Description
Factory setting
UPF
Multi-Output 2 (Optical couple output)
DRV
Multi-Output 1 (Optical couple output)
DC24V/100mA
DCM
Common Terminal of Digital and Control Signals, Â
SPL
Multi-Input 6
Low Speed
SPM
Multi-Input 5
Middle Speed
SPH
Multi-Input 4
High speed
RST
Multi-Input 3
Reset
REV
Multi-Input 2
Reverse run
FOR
Multi-Input 1
Forward run
ACM
Common Terminal of Analog and Control Signals
VO
Output voltage
+10
Power Supply for Speed Setting
+10VÂ
FA(EFA),
FB(EFB),
FC(EFC)
Multi-Output 3 (N/O or N/C)
3A/250VAC, 3A/30VDC
KA(EKA),
KB(EKB)
Multi-Output 4 (N/O)
3A/250VAC, 3A/30VDC
AI
Analog Current Frequency Reference InputÂ
4~20mA corresponding to the highest operating frequency
VI
Analog Voltage Frequency Reference InputÂ
0~+10V corresponding to the   highest operating frequency
AO
Output current
RS+Â RS-
RS485 Communication port